Network Power Divisions: 
power filters Control Concepts





















RoHS Compliancy List

Control Concepts manufactures power filters, surge protection, and lightning protection products for companies having power quality issues such as spikes, transients, and surges. Our patented Islatrol Active Tracking® Filters, as well as our surge protection products, are ideal for many applications.






printable page



Islatrol Series-connected high-frequency noise filter with transient protection. Offers the flexibility of either receptacle/line cord connection or hard-wired connection to critical loads (up to 30 amperes). Applications for this active tracking filter include industrial or office equipment, computers placed in harsh environments.

Typically reduces normal mode transients to
+/– 2 volts
Surge current capacity—45,000 Amps
Transient protection in all modes: line to neutral, line to ground, and neutral to ground
LED power indication
UL 1283, CSA recognized
10-year warranty

MCOV

  120 Volt
150 VRMS
  240 Volt
275 VRMS
Line Frequency
47–63 Hz
Response Time
  Normal Mode
< 0.5 ns
  Common Mode
< 5 ns
Operating Temperature
  –40ºC to +45ºC at Full Load
  Derate Linearly to 60% at +70ºC
Operating Humidity
0% to 95%
Peak Surge Current Capability (8 x 20 µs)
  Line to Neutral
15,000 Amps
  Line to Ground
15,000 Amps
  Neutral to Ground
15,000 Amps
Load Surge Current Rating
  10 mSec
5 x Nominal
  1 sec
3 x Nominal
  10 Sec
2 x Nominal
Packaging

  • High-Impact Plastic Case
  • Vacuum Impregnated Magnetics
  • Epoxy Encapsulated

Frequency Response
(Forward-Reverse)
  Normal Mode
100 kHz to 50 MHz—
90 dB Min
  Common Mode
5 MHz to 50 MHz—
60 dB Min
Typical Category A Ringwave
(6 kV, 200A, 100 kHz)

MODEL
NORMAL
COMMON
IC+102 / LRIC+102
1.0 / 0.9
302 / 287
IC+105 / LRIC+105
0.7 / 0.8
292 / 307
IC+107 / LRIC+107
0.7 / 0.7
302 / 293
IC+115 / LRIC+115
0.7 / 0.7
304 / 306
IC+130 / IC+202
0.5 / 1.1
306 / 536
IC+205 / IC+207
1.5 / 0.8
628 / 616
IC+215 / IC+230
0.6 / 0.9
572 / 566

Typical Category B Ringwave
(6 kV, 500A, 100 kHz)

MODEL
NORMAL
COMMON
IC+102 / LRIC+102
178 / 188
302 / 285
IC+105 / LRIC+105
162 / 191
291 / 300
IC+107 / LRIC+107
173 / 190
300 / 298
IC+115 / LRIC+115
153 / 149
307 / 309
IC+130 / IC+202
241 / 302
299 / 532
IC+205 / IC+207
378 / 336
594 / 596
IC+215 / IC+230
272 / 342
548 / 578

Note: All measurements in volts. IEEE test results with no AC applied. Normal mode—L1-N or L1-L2; Common mode—L-G, N-G or L1-G, L2-G.



120 VAC Models with Barrier Strip at Input & Output / with Wire Leads at Input & Output (WL)
MODEL
RATED OUTPUT
(AMPS)
CASE DIM. (in.)
A x B x C
MOUNTING FLANGE DIM. (in.)
D x E x F x G
SCREW SIZE
WGHT. (lbs.)
IC+102/IC+102WL
2.5
4x2.88x1.81
4.38x2.12x5.31x0.19
#6
1.0
IC+105/IC+105WL
5.0
4x2.88x1.81
4.38x2.12x5.31x0.19
#6
1.3
IC+107/IC+107WL
7.5
4.75x4.75x2.35
5.25x3.50x6.25x0.19
#6
2.0
IC+115/IC+115WL
15
6.25x4.75x2.35
6.75x3.50x7.75x0.19
#8
3.5
IC+130/IC+130WL
30
7.75x4.75x2.35
8.25x3.50x9.00x0.19
#8
6.0

120 VAC Models with 5-Foot Line Cord & Single NEMA 5-15 Receptacle
MODEL
RATED OUTPUT
(AMPS)
CASE DIM. (in.)
A x B x C
MOUNTING FLANGE DIM. (in.)
D x E x F x G
SCREW SIZE
WGHT. (lbs.)
LRIC+102
2.5
4.5x3.0x1.88
N/A
N/A
1.3
LRIC+105
5.0
4.5x4.5x2.38
N/A
N/A
2.0
LRIC+107
7.5
6.0x4.5x2.38
N/A
N/A
2.3
LRIC+115
15
7.5x4.5x2.38
N/A
N/A
4.0

240 VAC Models with Barrier Strip at Input & Output / with Wire Leads at Input & Output (WL)
MODEL
RATED OUTPUT
(AMPS)
CASE DIM. (in.)
A x B x C
MOUNTING FLANGE DIM. (in.)
D x E x F x G
SCREW SIZE
WGHT. (lbs.)
IC+202/IC+202WL
2.5
4x2.88x1.81
4.38x2.12x5.31x0.19
#6
1.3
IC+205/IC+205WL
5.0
4.75x4.75x2.35
5.25x3.50x6.25x0.19
#6
2.0
IC+207/IC+207WL
7.5
6.25x4.75x2.35
6.75x3.50x7.75x0.19
#8
3.3
IC+215/IC+215WL
15
7.75x4.75x2.35
8.25x3.50x9.00x0.19
#8
5.8
IC+230/IC+230WL
30
7.75x4.75x2.35
8.25x3.50x9.00x0.19
#8
6.0


 

 




Copyright © 2005 Control Concepts Corporation