Series-connected high-frequency noise filter with transient protection. Offers the flexibility of either receptacle/line cord connection or hard-wired connection to critical loads (up to 30 amperes). Applications include industrial or office equipment, computers placed in harsh environments.

Typically reduces normal mode transients to
+/– 2 volts
Surge current capacity—45,000 Amps
Transient protection in all modes: line to neutral, line to ground, and neutral to ground
LED power indication
UL 1283, CSA recognized
10-year warranty

MCOV

  120 Volt
150 VRMS
  240 Volt
275 VRMS
Line Frequency
47–63 Hz
Response Time
  Normal Mode
< 0.5 ns
  Common Mode
< 5 ns
Operating Temperature
  –40ºC to +45ºC at Full Load
  Derate Linearly to 60% at +70ºC
Operating Humidity
0% to 95%
Peak Surge Current Capability (8 x 20 µs)
  Line to Neutral
15,000 Amps
  Line to Ground
15,000 Amps
  Neutral to Ground
15,000 Amps
Load Surge Current Rating
  10 mSec
5 x Nominal
  1 sec
3 x Nominal
  10 Sec
2 x Nominal
Packaging

  • High-Impact Plastic Case
  • Vacuum Impregnated Magnetics
  • Epoxy Encapsulated

Frequency Response
(Forward-Reverse)
  Normal Mode
100 kHz to 50 MHz—
90 dB Min
  Common Mode
5 MHz to 50 MHz—
60 dB Min
Typical Category A Ringwave
(6 kV, 200A, 100 kHz)

MODEL
NORMAL
COMMON
IC+102 / LRIC+102
1.0 / 0.9
302 / 287
IC+105 / LRIC+105
0.7 / 0.8
292 / 307
IC+107 / LRIC+107
0.7 / 0.7
302 / 293
IC+115 / LRIC+115
0.7 / 0.7
304 / 306
IC+130 / IC+202
0.5 / 1.1
306 / 536
IC+205 / IC+207
1.5 / 0.8
628 / 616
IC+215 / IC+230
0.6 / 0.9
572 / 566

Typical Category B Ringwave
(6 kV, 500A, 100 kHz)

MODEL
NORMAL
COMMON
IC+102 / LRIC+102
178 / 188
302 / 285
IC+105 / LRIC+105
162 / 191
291 / 300
IC+107 / LRIC+107
173 / 190
300 / 298
IC+115 / LRIC+115
153 / 149
307 / 309
IC+130 / IC+202
241 / 302
299 / 532
IC+205 / IC+207
378 / 336
594 / 596
IC+215 / IC+230
272 / 342
548 / 578

Note: All measurements in volts. IEEE test results with no AC applied. Normal mode—L1-N or L1-L2; Common mode—L-G, N-G or L1-G, L2-G.



120 VAC Models with Barrier Strip at Input & Output / with Wire Leads at Input & Output (WL)
MODEL
RATED OUTPUT
(AMPS)
CASE DIM. (in.)
A x B x C
MOUNTING FLANGE DIM. (in.)
D x E x F x G
SCREW SIZE
WGHT. (lbs.)
IC+102/IC+102WL
2.5
4x2.88x1.81
4.38x2.12x5.31x0.19
#6
1.0
IC+105/IC+105WL
5.0
4x2.88x1.81
4.38x2.12x5.31x0.19
#6
1.3
IC+107/IC+107WL
7.5
4.75x4.75x2.35
5.25x3.50x6.25x0.19
#6
2.0
IC+115/IC+115WL
15
6.25x4.75x2.35
6.75x3.50x7.75x0.19
#8
3.5
IC+130/IC+130WL
30
7.75x4.75x2.35
8.25x3.50x9.00x0.19
#8
6.0

120 VAC Models with 5-Foot Line Cord & Single NEMA 5-15 Receptacle
MODEL
RATED OUTPUT
(AMPS)
CASE DIM. (in.)
A x B x C
MOUNTING FLANGE DIM. (in.)
D x E x F x G
SCREW SIZE
WGHT. (lbs.)
LRIC+102
2.5
4.5x3.0x1.88
N/A
N/A
1.3
LRIC+105
5.0
4.5x4.5x2.38
N/A
N/A
2.0
LRIC+107
7.5
6.0x4.5x2.38
N/A
N/A
2.3
LRIC+115
15
7.5x4.5x2.38
N/A
N/A
4.0

240 VAC Models with Barrier Strip at Input & Output / with Wire Leads at Input & Output (WL)
MODEL
RATED OUTPUT
(AMPS)
CASE DIM. (in.)
A x B x C
MOUNTING FLANGE DIM. (in.)
D x E x F x G
SCREW SIZE
WGHT. (lbs.)
IC+202/IC+202WL
2.5
4x2.88x1.81
4.38x2.12x5.31x0.19
#6
1.3
IC+205/IC+205WL
5.0
4.75x4.75x2.35
5.25x3.50x6.25x0.19
#6
2.0
IC+207/IC+207WL
7.5
6.25x4.75x2.35
6.75x3.50x7.75x0.19
#8
3.3
IC+215/IC+215WL
15
7.75x4.75x2.35
8.25x3.50x9.00x0.19
#8
5.8
IC+230/IC+230WL
30
7.75x4.75x2.35
8.25x3.50x9.00x0.19
#8
6.0